FLOW STAR BYPASS ROTAMETER |
| |
|
Suitable to measure the Flow in above 50NB Line Size Design Standard ISO 5167 or BS/1042 |

 |
Specification: - |
Accuracy : +/-2% of full flow
Rangeability : 7:1 or 5:1 |
Accessories: - |
High & Low Flow alarms |
Standard Material Of Construction :- |
Orifice Plate
Carrier Rings
Pipe Line
Wetted parts of the Rotameter |
SS-316 or PVC
SS-316 or Mild Steel or PP
SS-316 or Mild Steel
SS-316 or Mild Steel or PP |
|
| STANDARD RANGES FOR WATER AT 20°C |
| Series |
NW |
Maximum |
FBPR-1
FBPR-2
FBPR-3
FBPR-4
FBPR-5
FBPR-6
FBPR-7
FBPR-8
FBPR-9
FBPR-10
|
50
80
100
125
150
200
225
250
275
300 |
20 M3/HR.
36 M3/HR.
80 M3/HR.
125 M³/HR.
150 M³/HR.
320 M³/HR.
450 M³/HR.
550 M³/HR.
650 M³/HR.
800 M³/HR
|
|
|
| |
| MINIMUM UPSTRAIGHT LENGTHS REQUIRED |
Fitting Before Straight Run |
|
Diameter Ratio (B) |
| 0.2 |
0.25 |
0.3 |
0.35 |
0.4 |
0.45 |
0.5 |
0.55 |
0.6 |
0.65 |
0.7 |
0.75 |
Single 90° bend or Tee |
|
10 |
10 |
10 |
12 |
14 |
14 |
14 |
16 |
18 |
22 |
28 |
36 |
Two or more 90° bends in the same plane |
|
14 |
14 |
16 |
16 |
18 |
18 |
20 |
22 |
26 |
32 |
36 |
42 |
Two or more 90° bends in the same planes |
|
34 |
34 |
34 |
36 |
36 |
38 |
40 |
44 |
48 |
54 |
62 |
70 |
Reducers or Expanders |
|
16 |
16 |
16 |
16 |
16 |
18 |
20 |
20 |
22 |
24 |
26 |
28 |
Globe valve fully open |
|
18 |
18 |
18 |
18 |
20 |
20 |
22 |
24 |
26 |
28 |
32 |
36 |
Gate valve fully open |
|
12 |
12 |
12 |
12 |
12 |
12 |
12 |
14 |
16 |
16 |
20 |
24 |
MINIMUM DOWN STREAM STRAIGHT LENGTHS REQUIRED |
4 |
4 |
5 |
5 |
6 |
6 |
6 |
6 |
7 |
7 |
7 |
8 |
VALUES OF THE STRAIGHT LENGTH ARE OF 'D'
B=D/D D= ORIFICE DIAMETER D= INTERNAL DIAMETER OF PIPE
|
|
Details Require for Quotation |
-
NAME OF THE FLUID
-
OPERATING TEMPERATURE
-
OPERATING PRESSURE
-
OPERATING VISCOCITY/ DENSITY
-
LINE SIZE AND CONNECTION DETAIL
-
MEASURING RANGE
-
MATERIAL OF CONSTRUCTION FOR WETTED PARTS
|