FSD SERIES |

 |
• Dial Type Read Out
• Straight Flow Design
• No Bends
• No Seals, No Threaded Joints
• Direct Reading Scale
• Compact, Economical Design
• Perfect Safety |
OPERATING PRINCIPAL: |
The essential part is a tapered float with an imbedded magnet. When flow occurs, the position of the float responds to flow driving a follower magnet outside the meter body, with no physical contact. The meter works well with liquids even at elevated pressures and tempratures. Since there is only one moving part within the flow stream, no maintenance is required. |
APPLICATIONS: |
This meter Used in all process industries due to its ease of installation, perfect safety and easy maintenance. It may be used for monitoring flow of de-mineralized water, raw water, acids, salts, organic solvent and most petroleum products |
| SPECIFICATION MODEL - FSD |
Meter Body
Temp.Rsting
Float
Pressure Rating
Indicator Housing
Accuracy |
SS-316 or SS-304 or PTFE
250 C°
SS-316
30 KG/CM2
ALUMINIUM/ABS
+ 2% OF FULL SCALE
|
|
|